First, the operating instructions 1, according to the type of test sample, select the appropriate speed (100mm/min or 20mm/min).
2. Turn on the power switch and set the load value (out1) and load holding time (oyt) to be loaded on the control instrument. The specific operation steps are as follows:
Press and hold the “SET†key to enter the parameter settings, press the “MOD†key to convert each parameter, press the “<†key to enter the parameter, and use the “<â€, “∧†and “∨†keys to change the parameter setting value, force value parameter For AV, the time parameter is OYT; after setting, press “MOD†key to save, then hold “SET†key until return to the test state.
System default out1 unit is N
The default oyt unit of the system is 3 seconds. The position of the loading device is adjusted by “rising inching†and “dropping inching†so that the test sample can be smoothly installed and the sample required for testing can be installed in place according to the standard requirements.
4, press the "Start" button, the motor starts to pull the chuck to load the sample, while the instrument is automatically cleared. When the loaded load value reaches the set value out1, the instrument automatically starts the countdown clock and is displayed in the second window of the instrument.
When the countdown time reaches 0, the motor drives the chuck to be automatically unloaded. Press the "" key for 2 seconds and the motor stops. Remove the sample, observe and record the sample status.
At the end of the test, press the "" key to switch the display peak.
5. Repeat the above steps to test the next sample.
Second, the use of Note 1, the instrument on the instrument has two display windows, the first window shows the sensor force value, the unit is N; the second window shows the countdown time, in seconds.
2. Before the test, please warm up for 15 minutes.
3, when the instrument is running, please do not put the head, hands, etc. close to the chuck and moving parts to avoid injury.
4, non-professional maintenance personnel shall not open the cover to disassemble, change the internal electrical devices.
5. In case of emergency, please quickly press the emergency stop button and cut off the total power. Remove the fault and turn it on again.
6, the instrument power supply for single-phase AC power, must have a reliable grounding line.
7. The dynamic test part of the instrument is provided with upper (lower) limit stroke protection. When the loading device is operated to the upper (lower) limit position, it will be protected. At this time, it is necessary to press “Reset†(“Startâ€) or "Drop In" ("Drop In") lowers (raises) the loading device a distance.
8. The “reset†button on the operation panel can only be used after the end of a test, ie, the indicator light flashes, and the beep is 10s. To stop the test midway, use the “clear†key.
This article is the original article of Qingdao Zhongbang Instrument Co., Ltd. If you need to reprint it, be sure to add the source of the description. Reproduce the misappropriation without permission.
A toilet tank, also known as a hidden cistern, is a modern plumbing fixture used in bathrooms and toilets. It is designed to hide the flushing mechanism behind a wall or inside a piece of furniture, providing a sleek and minimalist look to the bathroom space.
The main purpose of a concealed flush tank is to save space and create a clean aesthetic by concealing the unsightly plumbing components typically associated with traditional exposed cisterns. By integrating the flush tank within the wall or furniture, only the flush buttons or plates are visible to the user.
Concealed cisterns come in various designs and sizes to accommodate different installation requirements. They are usually made of durable materials such as ABS plastic or stainless steel to ensure longevity and resistance to water damage. The tanks are equipped with a water inlet valve, a flushing mechanism, and an outlet pipe connected to the toilet bowl.
In addition to the aesthetic benefits, installation systems also offer practical advantages. They are typically equipped with dual-flush mechanisms, allowing users to choose between a full flush for solid waste and a partial flush for liquid waste. This dual-flush feature helps in conserving water by reducing the amount used for each flush, contributing to water efficiency and environmental sustainability.
Installation of a concealed cistern requires professional plumbing expertise, as it involves cutting into the wall and connecting the tank to the toilet bowl. However, once properly installed, the maintenance and upkeep of a concealed toilet tank are relatively straightforward.
Toilet Tank, Installation System,Toilet Water Tank,Toilet Cistern, Concealed Cistern
Guangdong Fabia Intelligent Technology Co., Ltd , https://www.fabiaintelligent.com